MFG #LPJ-6SP
UPC #05171252326
SKU #24800
Product description
BUSS LPJ-6SP 6A600V J LOW-PEAK FUSE
Bussmann Low-Peakâ„¢ Time Delay Fuse, Current Limiting, Series: LPJ-SP, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 6 A, 600 VAC/300 VDC, 100/300 kA Interrupt, Class: J, 10 s at 500% Response, Ferrule Terminal, Holder Mount, Cartridge Body Type, Dual Element, Melamine, 0.81 in Dia x 2.25 in L Body Size
Bussmann Low-Peakâ„¢ Time Delay Fuse, Current Limiting, Series: LPJ-SP, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 6 A, 600 VAC/300 VDC, 100/300 kA Interrupt, Class: J, 10 s at 500% Response, Ferrule Terminal, Holder Mount, Cartridge Body Type, Dual Element, Melamine, 0.81 in Dia x 2.25 in L Body Size
- Power Panelboard, Branch Circuit Breaker Panelboard Mains, Machinery Disconnects and Industrial Control, Safety and Security Systems
- Bussmann Low-Peakâ„¢ Time Delay Fuse, Current Limiting, Series: LPJ-SP, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 6 A, 600 VAC/300 VDC, 100/300 kA Interrupt, Class: J, 10 s at 500% Response, Ferrule Terminal, Holder Mount, Cartridge Body Type, Dual Element, Melamine, 0.81 in Dia x 2.25 in L Body Size
- Selective coordination ratio of 2:1 (within Low-Peak® fuse family) prevents electrical shutdowns from extending beyond the failed circuit
Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer
Proper sizing can provide "No Damage" type 2 coordinated protection for NEMA® and IEC® motor controllers
Space saving package for equipment down sizing
Industry's only UL listed and CSA Certified fuse with a 300 kA interrupt rating that allows for simple, worry free installation in virtually any application
Fast short circuit protection and dual element, time delay performance provide ultimate protection
Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak® fuses
Consistent 2:1 ampacity ratios for all Low-Peak® fuses make selective coordination easy
Long time delay minimizes needless fuse openings due to temporary overloads and transient surges
Current limitation protects downstream components against damaging thermal and magnetic effects of short circuit currents
Dual element fuses have lower resistance than ordinary fuses, hence they run cooler
They can often be sized for back up protection against motor burnout from overload or single phasing if other overload protective devices fail
- FUSE DLY TIME 6A 600 VAC/300 VDC J CRTG
- Product Catalog Page(s)
Specification Sheet
- CE Certified|CSA 1422-02/File No. 53787/J per CSA C22.2 No. 248.8|RoHS Compliant|UL File No. E4273|UL Guide JDDZ|UL Listed
- Brand:Â BUSSMANNAmperage Rating:Â 6 AApplication:Â Ind Facilities & Factories - Facility: Safety and Security SystemsClass:Â Class JConnection:Â Ferrule End X Ferrule EndCountry of Origin:Â MULElement:Â DualInterrupt Rating:Â 300 kAIC at 600 Vac100 kAIC VdcResponse Time:Â 10 sec at 500%Size:Â 0.81 In Diameter X 2.25 In LengthSpecial Features:Â Non-indicating, High in-rush current motor protectionStandard:Â CE Certified|CSA 1422-02/File No. 53787/J per CSA C22.2 No. 248.8|RoHS Compliant|UL File No. E4273|UL Guide JDDZ|UL ListedSub Brand:Â Bussmann SeriesType:Â FuseType Of Indicators:Â Non-IndicatingVoltage Rating:Â 600 Vac, 300 Vdc