MFG #L5F13D1DG2
UPC #07827515172
SKU #4386432
Product description
INTR L5F13D1DG2 SURGE PROTECTIVE DEVICE, 4-MODE, 120/240 VAC 3PH HIGH LEG DELTA, TYPE 1, AUDIBLE ALARM, FORM C CONTACT, SURGE CURRENT RATING 50KA
Intermatic® PanelGaurd™ Surge Protective Device, Series: L5 Series, 120/240 Highleg Delta V Electrical Rating, 50/60 Hz Frequency, 4+G Wires, 200 kA Short Circuit, 50 kA Peak Surge Current, 150 V (L-N)/150 V (L-G)/320 V (L-L)/150 V (N-G)/320 V (Hi-Leg) Clamping, 20 kA Nominal Discharge, Modes of Protection: L-G/L-L/L-N/N-G, Blue/Red LED Indicator, 3 ph, Environmental Conditions: -40 to 176 deg F, NEMA 4X/IP65 Enclosure, Lead Wire Terminal, Gray, 4.81 in W x 3.54 in D x 6.46 in H Dimensions
Intermatic® PanelGaurd™ Surge Protective Device, Series: L5 Series, 120/240 Highleg Delta V Electrical Rating, 50/60 Hz Frequency, 4+G Wires, 200 kA Short Circuit, 50 kA Peak Surge Current, 150 V (L-N)/150 V (L-G)/320 V (L-L)/150 V (N-G)/320 V (Hi-Leg) Clamping, 20 kA Nominal Discharge, Modes of Protection: L-G/L-L/L-N/N-G, Blue/Red LED Indicator, 3 ph, Environmental Conditions: -40 to 176 deg F, NEMA 4X/IP65 Enclosure, Lead Wire Terminal, Gray, 4.81 in W x 3.54 in D x 6.46 in H Dimensions
- Commercial/Industrial, Electrical Distribution Panels, Motor Control, Panel Boards, Switchboards, Switchgear, Transfer Switches, Service Entrance, HVAC Equipment Protection and Indoor/Outdoor Applications
- Intermatic® PanelGaurd™ Surge Protective Device, Series: L5 Series, 120/240 Highleg Delta V Electrical Rating, 50/60 Hz Frequency, 4+G Wires, 200 kA Short Circuit, 50 kA Peak Surge Current, 150 V (L-N)/150 V (L-G)/320 V (L-L)/150 V (N-G)/320 V (Hi-Leg) Clamping, 20 kA Nominal Discharge, Modes of Protection: L-G/L-L/L-N/N-G, Blue/Red LED Indicator, 3 ph, Environmental Conditions: -40 to 176 deg F, NEMA 4X/IP65 Enclosure, Lead Wire Terminal, Gray, 4.81 in W x 3.54 in D x 6.46 in H Dimensions
- DEVICE PROT SRG 120/240 HIGHLEG DELTA V
- Specification Sheet
- RoHS|ANSI/UL 1449 4th Edition|CSA C22.2 No. 269.1-14 (VZCA, VZCA7)|2020 National Electric Code|Article 242 (previously NEC, Art. 285), 700.10 & 708.20|ANSI/IEEE C62.72-2016|ANSI/IEEE C62.41.1|C62.41.2-2002|C62.45-2002|ANSI/IEEE C62.62-2010 environments: Categories: A, B & C|NFPA 780 & UL 96A Lightning protection systems
- Brand:Â IntermaticApplication:Â Electrical Distribution Panels;Motor Control;Panel Boards;Switchboards;Switchgear;Transfer SwitchesCountry of Origin:Â USPhase:Â 3 Phase High Leg Delta 120/240 VShort Circuit Rating:Â 200 kAType:Â NEMA Type 4XType Of Indicators:Â Blue/Red LED