MFG #FRS-R90
UPC #05171250842
SKU #23997
1 in Stock
Special Order Item. Minimum purchase may be required.
More available 01/12/2025
$155.30 per EA (1)Â /Â EA
Product description
BUSS FRS-R90 90A600V RK5 FUSETRON FUSE
Bussmann Fusetronâ„¢ Time Delay Fuse, Advanced Protection Current Limiting Energy Efficient Low Voltage, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 90 A, 600 VAC/300 VDC, 20/200 kA Interrupt, Class: RK5, 10 s at 500% Response, Blade Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.11 in Dia x 7.88 in L Body Size
Bussmann Fusetronâ„¢ Time Delay Fuse, Advanced Protection Current Limiting Energy Efficient Low Voltage, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 90 A, 600 VAC/300 VDC, 20/200 kA Interrupt, Class: RK5, 10 s at 500% Response, Blade Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.11 in Dia x 7.88 in L Body Size
- Branch Circuit, Power Panelboard, Motor Control Centers, Combination Starter and Machinery Disconnects, Safety and Security Systems
- Bussmann Fusetronâ„¢ Time Delay Fuse, Advanced Protection Current Limiting Energy Efficient Low Voltage, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 90 A, 600 VAC/300 VDC, 20/200 kA Interrupt, Class: RK5, 10 s at 500% Response, Blade Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.11 in Dia x 7.88 in L Body Size
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
Offers a 10 sec time delay at 5 times the rated current
The time-delay feature makes it possible to use fuse amp ratings that are much smaller than those of non-time delay fuses
Provides a good deg of short circuit protection (greater current- limitation to help protect downstream components from high fault currents
Gives motor running back-up protection to motors without extra cost
Helps protect motors against burnout from overloads and single phasing when sized properly
Simplifies and improves blackout prevention (selective coordination ratios)
- FUSE DLY TIME 90A 600 VAC/300 VDC RK5 BL
- Product Catalog Page(s)
Specification Sheet
- CE Certified|CSA C22.2 No. 248.12/1422-02/File No. 53787|UL 248-12/File No. E4273|UL Guide JDDZ
- Brand:Â BUSSMANNAmperage Rating:Â 90 AApplication:Â Ind Facilities & Factories - Facility: Safety and Security SystemsClass:Â Class RK5Connection:Â Blade end x blade endCountry of Origin:Â MXElement:Â DualInterrupt Rating:Â 200 kAIC at 600 Vac20 kAIC at 300 VdcResponse Time:Â 10 S at 500%Size:Â 1.11 In Diameter X 7.88 In LengthSpecial Features:Â RenewableStandard:Â CE Certified|CSA C22.2 No. 248.12/1422-02/File No. 53787|UL 248-12/File No. E4273|UL Guide JDDZSub Brand:Â Bussmann SeriesType:Â FuseType Of Indicators:Â Non-IndicatingVoltage Rating:Â 600 Vac, 300 Vdc